Ambulatory Blood Pressure Monitoring1
Light and Slim Design | All-Round Health Management2
HUAWEI WATCH D2 mesmerises with its 1.82" AMOLED display and 1500-nit peak brightness, but it's even more than meets the eye — telling you about your health at a moment's notice.
Turn your watch into a timeless timepiece, with style watch faces and an Always-on Display (AOD) at your beck and call. You can even personalise the watch face to keep your most-used features literally close at hand.8 With so many breathtaking watch faces to choose from, you can wear your heart on your sleeve and passions on your wrist!9
Start a 24-hour auto-monitoring plan anytime, to see where your BP has been and where it's trending, even while you're asleep. High-level data like average SBP and DBP readings during the day, at night, and over the past 24 hours, as well as accurate pulse rates, provide a new level of insight.
Take your BP the fast and easy way, on HUAWEI WATCH D2. You can also have the watch monitor your BP at regular intervals, whether you're sitting at your desk, watching a movie, or fast asleep.1
The watch's brand-new TruSense system is bolstered by a high-precision pressure sensor, mini pump, and inflatable airbag, to provide precise BP measurements that don't miss a beat.1
The watch measures vital signs with greater speed and accuracy, thanks to a multi-region optical path design, cutting-edge optical architecture, ultra-precision glass darkening technology, and next-gen health monitoring algorithms.
HUAWEI TruSense is now capable of monitoring six major systems, including the respiratory, nervous, and endocrine systems, to make digital health more accessible and comprehensive for all.
The 2-in-1 design packs a 26.5 mm ultra-narrow mechanical airbag6 that fits snugly and inflates with ease. It's also sweat-wicking and skin-soothing, and can be removed and replaced with just a press of the Quick Release button.
Get comprehensive Health Glance reports in just a few moments with 10 key indicators, including a brand-new emotional health metric. You can even browse graphs and charts to see what your body is telling you right away.4
*Availability of health indicators may vary in different countries and regions.
Clear your mind with a special Sleep mode,
white noise, natural soundscapes, and
relaxing music, to rest easy every night.10
HUAWEI WATCH D2's average heart rate
variability (HRV) metric assesses how well
you've recovered overnight, and can be used
with sleep heart rate, respiratory rate, and
SpO2 to paint a fuller picture of how your
body is holding up. The watch even monitors
abnormal breathing during sleep11, so that you can
enjoy greater peace of mind at all hours.
Browse high-level assessments to see how
well you've slept, and try out the custom
sleep hygiene tips to start sleeping better
right away and bring your life into better
balance.
Create a Health community of family and loved ones, to check BP, heart rate, SpO₂, daily step counts, and sleep quality from one easy place.17
HUAWEI WATCH D2 users are eligible for a free 3-month membership to HUAWEI Health+, which gives you access to a wealth of exclusive benefits, including workouts from beginner to advanced, guided meditations, Stay Fit Plan, Sleep music, and Breathing exercises.18
The battery can last for up to 6 days given typical usage.22
*The battery can last for up to 1 day with the ABPM feature enabled.22
6 days
Battery life given
typical usage
HUAWEI WATCH D2 is compatible with both iOS and Android, for greater ease of use.7
Measurement posture
The measurement posture refers to the posture that is maintained from the beginning of a measurement until the time when the device displays the measurement result. Any action that goes strays from the recommended posture may affect the measurement result.
The following are the guidelines for standard single blood pressure measurement posture:
The following are the guidelines for standard ambulatory blood pressure monitoring (ABPM) posture:
Applicable wrist circumference
M-sized strap: 13.0–16.0 cm
L-sized strap: 16.1–21.0 cm
Note: Please select the appropriate airbag for your wrist circumference. If your wrist circumference is less than 13.0 cm or more than 21.0 cm, the accuracy of blood pressure measurements may be affected.
Touch or scan the QR code to view more instructions.
*About Ambulatory Blood Pressure Monitoring (ABPM):
This feature measures your blood pressure (BP) at preset intervals
over a 24-hour period, and calculates your averages for the whole day,
daytime, and nighttime, and analyzes your BP rhythm. This data is used
for hypertension and cardiovascular risk assessment.
ABPM is recommended for users whose highest pressure stands at 120
mmHg or above on average or lowest pressure stands at 80 mmHg or above
on average, and for users whose doctor recommends ABPM. Measurement
frequency can be increased if necessary.
During this 24-hour period, BP measurements will be taken frequently
during which you'll need to stay at rest. Therefore, it is therefore
recommended that you choose a less busy day to conduct this plan, for
best possible results.
Warnings
• This device has not been validated for use on newborn babies or those who are pregnant.
• If your wrist circumference is less than 13.0 cm or more than 21.0 cm, the accuracy of blood pressure measurements may be affected.
• NEVER diagnose, treat yourself, or adjust your medications based on the readings of this device. ALWAYS consult with your physician and take medicines as prescribed. ONLY a physician is qualified to diagnose and treat high blood pressure.
• Do not use this device if you are allergic to nylon, fluororubber, or thermoplastic polyurethanes.
• Do not wear this device when receiving intravenous infusions or blood transfusions, or when having a catheter inserted through the wrist, as doing so may restrict blood flow and cause injury.
• Do not use this device if your wrist is wounded or if you are undergoing medical treatment as this may cause further injury.
• Consult with your physician before using this device if you have had a mastectomy or lymph node dissection.
• Consult with your physician before using this device if you are undergoing intravascular intervention or treatment, or if you have an arteriovenous (A-V) shunt, as doing so may temporarily restrict blood flow and cause injury.
• Ensure that this device is not restricting blood flow by observing the arm when taking blood pressure measurements.
• Do not take blood pressure measurements too often as bruising may occur if your blood flow is being restricted.
• Prolonged wear may cause friction or pressure which may irritate your skin. Please remove this device from time to time to let your wrist rest.
• This device may temporarily compromise other electrical medical monitoring equipment being used simultaneously on the same arm.
• Do not place this device near portable or mobile radio frequency communication equipment, as this may affect the functions and accuracy of this device.
• Do not use this device near high frequency surgical equipment, magnetic resonance imaging equipment, or computerized tomography scanners, as this may affect the functions and accuracy of this device.
• Do not use this device in an oxygen-rich environment or close to flammable gases.
• Keep the charging cradle and power cable away from newborn babies, infants, and children to minimize the risk of strangulation.
• Keep this device away from newborn babies, infants, and children as it contains many small parts which may be a choking hazard.
• Do not disassemble or tamper with this device, as this may damage it and/or cause injury.
• This device comes with a non-removable battery. Do not try to replace or fix the battery within its service life, as doing so may damage this device and/or cause injury.
• Do not use any accessories, transducers, or cables other than the ones specified or provided by the manufacturer of this device, as doing so could increase electromagnetic emissions or decrease electromagnetic immunity.
• Do not use this device while it is next to, underneath, or on top of another device unless it is absolutely necessary to do so, and even then, only with proper supervision of both devices.
• This device is designed for personal use. It is not to be used in healthcare centers where it would be in close proximity to high-frequency surgical equipment, outside the RF-shielded rooms next to MRI machines, or in places with high-frequency interference and high electromagnetic interference.
Precautions
• Keep this device clean. Stop using this device immediately and consult with your physician if it causes skin irritation or any other side effects.
• You may have an allergic reaction to this device. Stop using this device immediately and consult with your physician promptly if you experience any side effects from using this device.
• If the strap does not deflate after a blood pressure measurement, please remove the strap.
• Do not use this device with other medical electrical equipment, as this may affect the functions and accuracy of this device.
• Consult with your physician before using this device if you have arrhythmias (such as atrial or ventricular premature beats, or atrial fibrillation), arteriosclerosis, malperfusion, diabetes, pre-eclampsia, or kidney disease. Any of these conditions may affect the accuracy of blood pressure measurements.
• Moving or trembling during a blood pressure measurement may affect the accuracy of the measurement.
• This device has been carefully tested. It can reach the required level of accuracy for blood pressure measurements, and it has been approved for use for the duration of its validity period. Its performance may deteriorate beyond the validity period.
• Users of this device should be intended operators, either patients or operators assisting patients, and features should be used in accordance with this guide. This device can be used by multiple users at different times in guest mode.
• By default, this device runs and monitors data in the background and automatically uploads related logs.
• Do not use this device in high-use environments such as medical clinics or physician offices.